TIBCO InConcert server fails to start with error of "Undefined status code 100042 for IC facility"

TIBCO InConcert server fails to start with error of "Undefined status code 100042 for IC facility"

book

Article ID: KB0090899

calendar_today

Updated On:

Products Versions
TIBCO InConcert -
Not Applicable -

Description

Resolution:
This happens only when IC_DATABASE_TRAN_MODE set to 1 and the database is Oracle.  The message says that TWO_TASK must be set before the server is started and that is a requirement when using IC_DATABASE_TRAN_MODE set to 1 regardless if the database is co-resident with the InConcert server.  This error will also happen on HP UX if env.sh or env.csh files in IC_HOME/config are not executed.  Only one has to be sourced.

Issue/Introduction

TIBCO InConcert server fails to start with error of "Undefined status code 100042 for IC facility"