When TIBCO Remedy adapter version 5.1.0 for AR System 6.0 is used on HP_UX machine, it is not possible to add remedy adapter palette to the designer view panel while configuring the design time adapter using TIBCO Designer.

When TIBCO Remedy adapter version 5.1.0 for AR System 6.0 is used on HP_UX machine, it is not possible to add remedy adapter palette to the designer view panel while configuring the design time adapter using TIBCO Designer.

book

Article ID: KB0090163

calendar_today

Updated On:

Products Versions
TIBCO Adapter for Remedy -
Not Applicable -

Description

Description:
Symptoms
========
When TIBCO Remedy adapter version 5.1.0 for AR System 6.0 is used on HP_UX machine, it is not possible to add remedy adapter  palette to the designer view panel while configuring the design time adapter using TIBCO Designer.
This issue will be observed when Remedy adapter v5.1.0 for AR System 6.0 is used on HPUX platform.

Impact
======
Loss of Functionality
Unable to configure the design time of adapter

Workaround
==========
Copy arapi60.jar from AR system installation and replace it at &ltadapter home>/5.1/lib. Or keep this file in a location and append this location of the file to “CUSTOM_CP_EXT” path in designer.tra. The location of arapi60.jar file in AR System  installation is &ltremedy home>

Cause
=====
The arapi60.jar shipped along with adapter is corrupted. (located at &ltadapter home>/5.1/lib)

Resolution
==========
We plan to address this issue in the next release/hotfix of the adapter.