TIBCO Adapter for Teradata 5.3.0 now supports Tibco Business Works 5.3.x, 5.4.0
book
Article ID: KB0090417
calendar_today
Updated On:
Products
Versions
TIBCO Adapter for Teradata
-
Not Applicable
-
Description
Description: TIBCO Adapter for Teradata 5.3.0 now supports TIBCO Business Works 5.3.x and 5.4.0, in addition to the currently supported versions, listed in the product documentation. The only TIBCO Business Works 5.3.x, 5.4.0 features supported by the adapter are those included in the documentation for TIBCO Adapter for Teradata 5.3.0.
No adapter configuration changes are required to use TIBCO Business Works 5.3.x, 5.4.0 with version 5.3.0 of the Teradata Adapter.
Known Issues: ============ BusinessWorks throws a serialization error for Custom RPC Invocation when a value for MAXROWS is not entered in the input tab during configuration
Symptoms: ========= BusinessWorks throws a serialization error for Custom RPC Invocation when a value for MAXROWS is not entered in the input tab during configuration. In case of Custom RPC the BusinessWorks process should not expect a value as it is already specified in Teradata Server.
Cause: ====== Specific incompatibility with BW 5.3.x and above working with the Adapter for Teradata 5.2.1 and above
Impact: ====== Older versions of Teradata adapter configurations may not work when upgraded to version 5.2.1 unless the "MAXROWS" value is specifically entered.
Workaround: =========== Please specify value for "MAXROWS' field as 0 which is the default value, under the input Tab of ‘Invoke an Adapter Request-Response Service’ activity.
Resolution ========= None. Change Requests (CR#1-7190YF for TIBCO Adapter for Teradata and CR#1-71GXNA for TIBCO BusinessWorks) have been logged to address this issue in a future release.
Issue/Introduction
TIBCO Adapter for Teradata 5.3.0 now supports Tibco Business Works 5.3.x, 5.4.0