What does it mean if I see this warning in my log file, TAL-SS-15151-W Timed out priming RTserver with name /_some_other_server_node_pid.

What does it mean if I see this warning in my log file, TAL-SS-15151-W Timed out priming RTserver with name /_some_other_server_node_pid.

book

Article ID: KB0090901

calendar_today

Updated On:

Products Versions
TIBCO SmartSockets -
Not Applicable -

Description

Resolution:
The RTservers were able to create a TCP level connection and a SmartSockets connection, but they were unable to initialize the information needed about the two servers to start the protocol between them on time. This information is called "priming" and includes entire subject tables, monitoring information, etc. . This could be a sign of one of one of the  RTservers being very busy or potentially a network related issue.

Issue/Introduction

What does it mean if I see this warning in my log file, TAL-SS-15151-W Timed out priming RTserver with name /_some_other_server_node_pid.