When TIBCO Adapter for MQSeries 5.1.0 is installed as an NTService it always take the run-time parameters from default TRA file.
book
Article ID: KB0091468
calendar_today
Updated On:
Products
Versions
TIBCO ActiveMatrix Adapter for Websphere MQ
-
Not Applicable
-
Description
Description: Symptoms: ========= When adapter is started from a pre-installed NT service configured to use a customized TRA file it always takes all the run-time parameters from the dafault TRA file present in $TIBCO/adapter/admqs/5.1/bin directory.
Impact: ====== Users can not use any modified TRA file with customized runtime parameters.
Cause: ====== This is an issue with the TIBCO Wrapper used for the 5.1.0 "admqs.exe".
Workaround: ========== For resolving the issue following steps should be followed:-
a) Replace the TIBCO adapter for MQSeries 5.1 excutable file "admqs.exe" with the one installed with TIBCO Adapter for MQSeries 5.2.
b) After replacemnet is done the service needs to be uninstalled and then re-installed using the required .tra file. Symptoms:
Cause:
Issue/Introduction
When TIBCO Adapter for MQSeries 5.1.0 is installed as an NTService it always take the run-time parameters from default TRA file.