On Linux, when using TRA 5.5.0 the adapter runtime executable cannot initialize properly and terminates
book
Article ID: KB0086607
calendar_today
Updated On:
Products
Versions
TIBCO Adapter for Teradata
-
Not Applicable
-
Description
Description: Known Issues: ============ 1) On Linux, when using TRA 5.5.0 the adapter runtime executable cannot initialize properly and terminates
Symptoms: ========== When using TRA 5.5.0 the adapter runtime executable cannot initialize properly and terminates after throwing an exception error message as indicated below. The cause of the error is a corrupted “tibicudata32.dat” file, which all adapters’ access on startup.
-Code = AESDKC-0128, Category = Unicode, Severity = errorRole, Description = Unicode conversion failure : Failed to convert type "LATIN_1" to Unicode - have you defined the env var TIB_ICU_DATA to point to the directory that contains tibicudata32.dat?, File = S/MUConverter.cpp, line = 166
Impact ========== Loss of functionality
Workaround ========== None
Resolution ========== Install HotFix1 for TRA 5.5.0 which has the corrected version of the “tibicudata32.dat” file. Please refer to LBN# LBN1-7MVX7L for more information on HotFix1 for TRA 5.5.0 Symptoms:
Cause:
Issue/Introduction
On Linux, when using TRA 5.5.0 the adapter runtime executable cannot initialize properly and terminates