TIBCO Adapter for Siebel 5.3.0 does not accepts value for Design-time Connection Parameter "User Name" and "Password" from the Global Variables specified.
book
Article ID: KB0086542
calendar_today
Updated On:
Products
Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for Siebel
-
Not Applicable
-
Description
Description: Symptom: ------------ When the connection parameters (User Name and Password) for the adapter design-time connection are specified as Global Variables, adapter throws below connection error.
AEADSBL-400035 Connection to Siebel Repository failed. [Startup Error.Unable to create a connection with the target application Siebel Server using connection parameters:userid = %%SiebeLoginName%%, Connect String = siebel.tcpip.none.zlib://. . . . . ., Language parameter= , application error : SBL-SEC-10018: You have entered an invalid setof logon parameters. Please type in your logon parameters again.(SBL-DAT-00446)]
Impact: ---------- Loss of functionality. This issue is particular to design time connection and works fine during the run time connection.
Workaround: ----------------- Enter the value of User Name and Password under Design-time Connection tab instead of Global Variables.
Resolution: -------------- The issue has been addressed in TIBCO Adapter for Siebel 5.3.1. Symptoms:
Cause:
Issue/Introduction
TIBCO Adapter for Siebel 5.3.0 does not accepts value for Design-time Connection Parameter "User Name" and "Password" from the Global Variables specified.