TIBCO Adapter for Siebel 5.3.1 supports TRA 5.5.2, TRA 5.5.3 and TRA 5.5.4

TIBCO Adapter for Siebel 5.3.1 supports TRA 5.5.2, TRA 5.5.3 and TRA 5.5.4

book

Article ID: KB0092289

calendar_today

Updated On:

Products Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for Siebel -
Not Applicable -

Description

Description:
TIBCO Adapter for Siebel 5.3.1 now supports TRA 5.5.2, TRA 5.5.3 and TRA 5.5.4, in addition to the currently supported TRA versions listed in the product documentation.  The only TRA features supported by the adapter are those included in the documentation for TIBCO Adapter for Siebel.  

No adapter configuration changes are required to use TRA 5.5.2, TRA 5.5.3 and TRA 5.5.4 with version 5.3.1 of the Siebel adapter.

Known Issues:

1) Designer throws Resource Skipped during Merge warning.

Symptoms
========
On dragging and dropping Siebel Adapter Configuration palette in the Design panel, designer throws a warning Resource Skipped during Merge. This warning will also come when a project is re-opened.

Impact
======
Just a warning. The adapter functionality is not affected. The warning can be ignored.

Workaround
==========
None

Resolution
==========
This issue will be addressed in future HotFix / adapter release

2) Designer throws 'Subject Validation Error'

Symptoms
========
When a project containing Siebel Adapter Instances is validated for Deployment, Designer throws subject validation errors for the default advisory endpoints that get created with subjects starting with _RV and _SDK.

Impact
======
Will not have any impact on the run-time Adapter. These errors can be ignored.

Workaround
==========
None

Resolution
==========
This issue will be addressed in future HotFix / adapter release

Issue/Introduction

TIBCO Adapter for Siebel 5.3.1 supports TRA 5.5.2, TRA 5.5.3 and TRA 5.5.4