Known Issue:Positional Flat Files from earlier release of SpecBuilder(e.g. 6.0 and earlier) would not work with EDI 5.2.0. You will see a guideline version error when running the transactions with BC.

Known Issue:Positional Flat Files from earlier release of SpecBuilder(e.g. 6.0 and earlier) would not work with EDI 5.2.0. You will see a guideline version error when running the transactions with BC.

book

Article ID: KB0093166

calendar_today

Updated On:

Products Versions
TIBCO BusinessConnect EDI Protocol Powered by Instream -
Not Applicable -

Description

Description:
Example of the error

---------------------
Brief:  : Guideline load error [ID=71000c]
Details:  The guideline version 106 is not supported. Please upgrade the guideline to 109 or a higher version.
ID:  71000c
---------------------


Solution:
======
With EDI 5.2.0, the Positional Flat File guideline should be updated with the SpecBuilder 6.2 version. Users should:

1.  Download the guideline .ecs file from the repository.  Save a copy of this file, as once you have updated it, it can not be used in prior versions of BC EDI.
2.  Open the .ecs guideline with SpecBuilder 6.2.  While opening the file, SpecBuilder will update the guideline.
3.  Save the revised guideline.
4.  Upload the changed .ecs to the Configuration GUI.
Symptoms:

Cause:

Issue/Introduction

Known Issue:Positional Flat Files from earlier release of SpecBuilder(e.g. 6.0 and earlier) would not work with EDI 5.2.0. You will see a guideline version error when running the transactions with BC.