Why does the R/3 adapter show 'Could not initialize dynamic link library librfc. Found version 640.0.117 but required at least version 640.0.161' when latest libraries are present in the specified directory.
book
Article ID: KB0093265
calendar_today
Updated On:
Products
Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for SAP Solutions
-
Not Applicable
-
Description
Resolution: This could happen if the system paths are pointing to other directories in which older versions of the librfc*.dll files are present. Please ensure the older files are not present in any other place eg: windows/system32. These files would also come along with the SAP GUI installation.
Issue/Introduction
Why does the R/3 adapter show 'Could not initialize dynamic link library librfc. Found version 640.0.117 but required at least version 640.0.161' when latest libraries are present in the specified directory.