Global Variables getting reset to the design time values on replacing the current deployed enterprise archive file with an updated version through the TIBCO Administrator

Global Variables getting reset to the design time values on replacing the current deployed enterprise archive file with an updated version through the TIBCO Administrator

book

Article ID: KB0093214

calendar_today

Updated On:

Products Versions
TIBCO Runtime Agent (TRA) -
Not Applicable -

Description

Description:
Symptom:
------------
On replacing the current deployed enterprise archive file(ear) with an updated version the values of the global variables previously set are lost and are reset to their design time values i.e. the value specified in the designer when the ear was generated.

Impact:
---------
This may lead to default values being used by the application. This is true for Administrator 5.4 using TRA 5.5.2.

Workaround:
------------------
Use AppManage to export deployment configuration file for the deployed application and use this xml file for configuring the application and uploading/deploying the new version of the ear.

Resolution:
--------------
A hot fix is scheduled to be released as soon as possible, please contact TIBCO Support for any questions or concerns. We would publish another LBN when the TRA HF is made available.
Symptoms:

Cause:

Issue/Introduction

Global Variables getting reset to the design time values on replacing the current deployed enterprise archive file with an updated version through the TIBCO Administrator

Attachments

Global Variables getting reset to the design time values on replacing the current deployed enterprise archive file with an updated version through the TIBCO Administrator get_app