In TIBCO Adapter for Tuxedo 5.6.0, sequence data may be lost a sequence is defined in Request Schema or Reply Schema.

In TIBCO Adapter for Tuxedo 5.6.0, sequence data may be lost a sequence is defined in Request Schema or Reply Schema.

book

Article ID: KB0090694

calendar_today

Updated On:

Products Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for Oracle Tuxedo -
Not Applicable -

Description

Resolution:
Symptoms
========
This problem can be seen when using adtuxedo 5.6.0 on any platform when you define sequence in request schema or reply schema.
>> For Publication service, adapter can only publish the FML32 field data which are not in a sequence.
>> For Request-Response service, adapter can't send back the sequence data in the reply data.  
>> For Request-Response Invocation Services, adapter can only receive th  FML32 field data which are not in the sequence.

>> All the fields defined under a sequence are received/sent empty.

Impact
======
Loss of Functionality.  The adapter could not receive or send the sequence data in the case of Publication, Request-Response and Request-Response Invocation services; sequence data is lost.

Workaround
==========
See Resolution

Cause
=====
The adapter was improperly using an SDK API

Resolution
==========
This issue has been resolved in TIBCO Adapter for Tuxedo Adapter 5.6 Hotfix 1. For details about this hotfix, please refer to LBN1-8O9W97

Issue/Introduction

In TIBCO Adapter for Tuxedo 5.6.0, sequence data may be lost a sequence is defined in Request Schema or Reply Schema.