TIBCO(R) Adapter for Siebel 5.3.1 now supports TIBCO Active Matrix Business Works 5.6.x, 5.7.x, 5.8.x, 5.9.x and 5.10.x.

TIBCO(R) Adapter for Siebel 5.3.1 now supports TIBCO Active Matrix Business Works 5.6.x, 5.7.x, 5.8.x, 5.9.x and 5.10.x.

book

Article ID: KB0091742

calendar_today

Updated On:

Products Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for Siebel -
Not Applicable -

Description

Description:
TIBCO(R) Adapter for Siebel 5.3.1 now supports TIBCO Active Matrix Business Works 5.6.x, 5.7.x, 5.8.x, 5.9.x and 5.10.x.  The only Business Works features supported by the adapter are those included in the documentation for TIBCO(R) Adapter for Siebel 5.3.1

TIBCO Active Matrix Business Works 5.6.x, 5.7.x, 5.8.x, 5.9.x and 5.10.x includes the following:

*TIBCO Active Matrix Business Works - Business Works engine that does not run as a Service Engine; for use by customers that are not using Active Matrix
*TIBCO Active Matrix Business Works Service Engine (BWSE) - Business Works Engine running as a Service Engine for use within Active Matrix

No adapter configuration changes are required to use TIBCO Active Matrix BusinessWorks.

For details on using TIBCO(R) Adapter for Siebel 5.3.1 with BWSE 5.6.x, 5.7.x, 5.8.x, 5.9.2 or higher 5.9.x,5.10.x, please refer to LBN1-8Y6BMF - How can standalone adapters interoperate with ActiveMatrix Business Works Service Engine (BWSE) 5.6.x, 5.7.x, 5.8.x, 5.9.x and 5.10.x?

Limitations and Restrictions:
===============================
Both 32-bit and 64-bit BusinessWorks executables are supported. If BusinessWorks and TIBCO Adapters will be installed on the same machine, the bitness of both products may need to be the same. Please check the adapter's product documentation and LBNs for any limitations regarding bitness Support.

Configuration Changes:
===============================
None

Known Issues:
------------------------
Issue:
TIBCO ActiveMatrix BusinessWorks Service Engine (BWSE) 5.6.0 will not initialize when the BW Services use native BW Bindings with TIBCO(R) Adapter for Siebel 5.3.1

Symptoms:
The BW engine running inside the Business Works Service Engine (BWSE) throws an exception at initialization time, indicating a failure to establish a JMS Connection, if it has a BW process that had a reference to a SIEBEL Adapter end-point.

Impact:
Loss of Functionality
You will be unable to start TIBCO ActiveMatrix BusinessWorks Service Engine

Workaround:
None

Cause:
TIBCO ActiveMatrix BusinessWorks Service Engine is unable to establish a JMS connection, so BWSE is unable to start.

Resolution
This issue has been resolved with TIBCO ActiveMatrix BusinessWorks ServiceEngine 5.6.1.

Issue/Introduction

TIBCO(R) Adapter for Siebel 5.3.1 now supports TIBCO Active Matrix Business Works 5.6.x, 5.7.x, 5.8.x, 5.9.x and 5.10.x.