Application shows the “starting up” status in the Administrator GUI, whether it was started from a script or the GUI, but its microagent is not registered.
book
Article ID: KB0090922
calendar_today
Updated On:
Products
Versions
TIBCO Administrator
-
Not Applicable
-
Description
Resolution: In the application .tra file, check that the following parameters have been set correctly.
Hawk.AMI.DisplayName: This needs to be set in the following format: COM.TIBCO.ADAPTER.bwengine.<domain name>.<deployed name>.<process archive name> Hawk.Enabled This needs to be set to true. Hawk.service This needs to be set to the AMI service value. Hawk.Network This needs to be set to the AMI Network value Hawk.Daemon. This needs to be set to the AMI Daemon value (check the domain hawkagent.cfg file to confirm what AMI values should be).
Issue/Introduction
Application shows the “starting up” status in the Administrator GUI, whether it was started from a script or the GUI, but its microagent is not registered.