Eliminating RV connections on default RV service-network-daemon parameters with the BC engine.

Eliminating RV connections on default RV service-network-daemon parameters with the BC engine.

book

Article ID: KB0091222

calendar_today

Updated On:

Products Versions
TIBCO BusinessConnect -
Not Applicable -

Description

Resolution:
By default, BC will spawn connection on RV service 7500 and daemon tcp:7500 to perform some of its internal processing.  These RV channels do not communicate with any other entity other the the BC engine itself.

If you would like to assign these connections to another RV channel, add the following lines to the deployed engine's TRA file:

Bus.Default.Service=&ltservice number>
Bus.Default.Network=&ltnetwork parameter>
Bus.Default.Daemon=tcp\:&lthostname>\:&lttcp port number>

Issue/Introduction