Implications of using"Engine.FT.UseFT" rather than "be.ft.enabled" in Fault Tolerance(FT).
book
Article ID: KB0091935
calendar_today
Updated On:
Products
Versions
TIBCO BusinessEvents Enterprise Edition
-
Not Applicable
-
Description
Resolution: Description: ============ How to clearly define the differences between the folloiwng 2 properties for BusinessEvents FT situations:
1). Engine.FT.UseFT 2). be.ft.enabled
Environment: ============ All
Symptoms: ======== Not applicable
Cause: ======== Not applicable
Resolution: ===========
Enabling FT in BusinessEvents(BE) using the system property "Engine.FT.UseFT" rather than "be.ft.enabled" causes BusinessWorks(BW) to go into FT mode as BW also utilizes the same property.
Use the following properties so that Engine.FT.UseFt related properties are disabled.
be.ft.enabled = true be.ft.cluster.name = ft_group_name #<integer> < lower the number the higher the priority.> #be.ft.priority = 1 #Engine.FT.UseFT = true #Engine.FT.GroupName = ft_group_name #<integer> < lower the number the higher the priority.> #Engine.FT.Weight=100
Issue/Introduction