What is the meaning of the error message: TAL-SS-10115-A rtserver: interrupted by SIGXFSZ signal (File Size Limit Exceeded)?
book
Article ID: KB0086242
calendar_today
Updated On:
Products
Versions
TIBCO SmartSockets
-
Not Applicable
-
Description
Resolution: The RTserver is reporting that it received a signal from the OS that a file size limit has been exceeded. This is likely to be a log file that the RTserver is creating. You can use "ulimit -a" to check the file size limit on your system, and then compare that to the file sizes of your log files by using "ls -l" in the directory where your log files are written.
If your RTserver trace file is very large then you should consider reducing the trace_level you are using or rotating logs when they reach a certain size. Trace_level values above Info_1 are only recommended during times of active debugging of a problem, and should only be enabled at the recommendation of TIBCO Support. If you are logging messages into and/or out of the RTserver we recommend that you disable this logging unless you are actively debugging a problem and have been instructed to perform logging by TIBCO Support.
Issue/Introduction
What is the meaning of the error message: TAL-SS-10115-A rtserver: interrupted by SIGXFSZ signal (File Size Limit Exceeded)?