This Late Breaking News item addresses known issues for TIBCO Runtime Agent 5.6.0. It is an addendum to the list of known issues listed in the associated release notes.
book
Article ID: KB0086857
calendar_today
Updated On:
Products
Versions
TIBCO Runtime Agent (TRA)
-
Not Applicable
-
Description
Description:
1-9DAITH
Missing tibicudata.dat in Solaris 10 x86 platform build of TRA 5.6.0 GA.
1-95YP6L
Buildear fails to start when TRA 5.6.0 is installed in a non-default location. When TRA 5.6.0 is installed on windows and unix into the non-default location (e.g. E:\tibco in lieu of the default location C:\tibco on windows) the buildear.tra still references the default location (e.g. tibco.include.tra C:/tibco/designer/5.6/bin/designer.tra).
Workaround: Manually edit the buildear.tra to reference the correct (non-default) location of the installation home.
1-95OPBC
Installation of TRA 5.6.0 on Windows in a folder that has spaces in the name is successful, but fails to launch the traDBConfig utility at the end. It throws an error that it cannot find the path to the utility.
Workaround: Manually run the traDBConfig utility.
1-95P0BV
In UNIX platform, TRA560 can not be installed to a folder whose name contain space char.
Workaround : None
1-931LH0
The release notes of TRA 5.6.0 has listed this CR in known issues without specifying a Workaround.
The workaround is same as that specified for 1-8A33V3 below.
1-8A33V3
The release notes of TRA 5.6.0 has listed this CR in known issues without specifying a Workaround.
Workaround: Only retain the libeay32.dll and ssleay32.dll installed in the RV directory and remove the same, if any, from other directories (such as Hawk, SDK, TPCL in TRA etc.). Symptoms:
Cause:
Issue/Introduction
This Late Breaking News item addresses known issues for TIBCO Runtime Agent 5.6.0. It is an addendum to the list of known issues listed in the associated release notes.