We cannot set the File Adapter log file size from the deployed TRA file. File Adapter debug level can only be enable using the TIBCO Designer by selecting the Adapter Instance -> logging Tab -> enable the Log Debug Messages.  Below are the instructions to follow to enable debug level and to specify the log file size in the TIBCO Designer:

1. Go to the File Adapter Configuration -> 'Logging' tab.
3. Check the 'Use Advance Logging' box. You will notice that all other options under that tab have now vanished.
4. Go to 'Advanced' --> 'Log Sinks'
5. Drag and drop a 'Generic Log Sink'
6. Under the 'Configuration' tab for this log sink, you can define the file size and file count.