How to modify an existing icconfig.xml when one is not correctly created on upgrade or installation.

How to modify an existing icconfig.xml when one is not correctly created on upgrade or installation.

book

Article ID: KB0092308

calendar_today

Updated On:

Products Versions
TIBCO InConcert -
Not Applicable -

Description

Resolution:
The begriming tab naming the server must be updated.  For example if the name of the installation was 'GG_DEV' then the name of the IC server  &ltGG_T400 id="1123"> becomes &ltGG_DEV id="XXXX"> where XXXX is the server ID value.  Put in the new Server ID value if that is different.  The ending tag, 'GG_T400', for the server must also be changed.
The ending tag to change is </GG_T400>.

Update &ltIC_HOME> with the correct IC_HOME directory.  Search the file for any instances of the existing IC_HOME and replace that directory.  You will need to update the debug log and audit log files locations.  Update IC_HOST_MACHINE with the correct name.

Issue/Introduction

How to modify an existing icconfig.xml when one is not correctly created on upgrade or installation.