Why does the TIBCO Adapter (TM) for Teradata throw the error message “Deprecated logons are not allowed by administrator. Upgrade client software to latest version.”?
book
Article ID: KB0092382
calendar_today
Updated On:
Products
Versions
TIBCO Adapter for Teradata
-
Not Applicable
-
Description
Resolution: This error message gets originated from the Teradata Gateway. It may occur when either the Teradata Client libraries are incorrect.
Below is the error description in the Teradata documentation. Please visit www.teradata.com for the Online Documentation. The below excerpt is available in the Teradata Database document titled - "Messages" ----------- 08071 Deprecated logons are not allowed by administrator. Upgrade client software to latest version. Explanation: The gateway detected a deprecated logon sequence and deprecated logons are not allowed. Upgrade the client application to a version which supports encrypted passwords or use gtwcontrol to allow deprecated logons. Generated By: Gateway For Whom: Field Engineer Remedy: Correct the configuration. If the problem persists, contact the National Support Center. ------------
The Teradata adapter uses the CLIv2 libraries, provided with the Connectivity Software by NCR, to establish the runtime connection to the Teradata Database.
Please download and install the latest compatible libraries from Teradata Download Center - CLI > <platform> - TTU <version> cliv2.