S0C4 in module HRNHLLTO followed by message HRNDR014E and shutdown of the Execution Environment or other unpredictable errors.
book
Article ID: KB0088351
calendar_today
Updated On:
Products
Versions
TIBCO ObjectStar Integration Foundation
-
Not Applicable
-
Description
Resolution: Description: Module HRNHLLTO incurs a storage violation resulting in abend S0C4 or other unpredictable results within an Execution Environment.
Environment: Occurs infrequently within an Execution Environment address space running on z/OS.
TIBCO Products Affected: TIBCO ObjectStar for z/OS 4.1.1 with PTFs AP11665 or AP11766 applied.
Symptoms: Messages as may appear on Execution Environment JES log: IEA995I SYMPTOM DUMP OUTPUT SYSTEM COMPLETION CODE=0C4 REASON CODE=00000004 TIME=13.37.33 SEQ=18679 CPU=0000 ASID=006C PSW AT TIME OF ERROR 078D0000 96C3AF06 ILC 4 INTC 04 ACTIVE LOAD MODULE ADDRESS=16C39C38 OFFSET=000012CE NAME=HRNHLLTO DATA AT PSW 16C3AF00 - B01C5040 10005040 208C0700 GR 0: 00000008 1: 00000000 2: 17FD7E30 3: 00000005 4: 0000000D 5: 00000000 6: 16C3AF40 7: 001E6918 8: 00000000 9: 00000000 A: 00007BB0 B: 31E38400 C: 96C3AE98 D: 001E6FB8 E: 00FD86F0 F: 16C3AFB6 END OF SYMPTOM DUMP
Followed by: HRNDR014E EE main task TCB has been terminated prematurely due to the unrecoverable error.
Cause: This error is caused by an error in HRNHLLTO error recovery ESTAE logic described by problem report CR 1-843NF3 and is corrected in TIBCO Object Service Broker for z/OS 5.0.0.
Resolution: Upgrade to TIBCO Object Service Broker for z/OS 5.0.0.
References: TIBCO problem report CR 1-843NF3.
Issue/Introduction
S0C4 in module HRNHLLTO followed by message HRNDR014E and shutdown of the Execution Environment or other unpredictable errors.