Resolution: Description: = = = = = = = After upgrading EMS to version 5.1.2 or higher the following error is seen when starting the EMS server with the SmartSockets bridge feature enabled:
“Unable to locate tutil50.dll”
Environment: = = = = = = = EMS 5.1.2 and later
Resolution: = = = = = = Enterprise Message Service versions 4.0.0 through 5.1.1 include statically linked copies of the SmartSockets client libraries within the server process. Enterprise Message Service version 5.1.2 dynamically loads the SmartSockets client libraries into the server process. If you are using the Enterprise Message Service server's SmartSockets support, you must enter a new parameter in the main tibemsd.conf configuration file to designate the location of the SmartSockets libraries:
where SmartSockets-shared-library-directory is the absolute path to the directory containing the SmartSockets libraries. For example: module_path = c:\tibco\ss68\bin\i86_w32 Please see the SmartSockets documentation to locate the directory in which the appropriate libraries are installed.