Deployment of BE engine fails on a Unix server for both inside and outside the administrator domain.

Deployment of BE engine fails on a Unix server for both inside and outside the administrator domain.

book

Article ID: KB0085413

calendar_today

Updated On:

Products Versions
TIBCO BusinessEvents Enterprise Edition -
Not Applicable -

Description

Resolution:
Description:
===========
Deployment of BusinessEvents engine fails on a Unix server for both inside and outside the administrator domain.

Environment:
===========
TIBCO BusinessEvents 3.x
Unix/Linux Systems


Resolution:
========
This issue (start of the engine fail without any log) could happen when the  Xms, Xmx, min heap and max heap size settings are incorrect. The  Min/max heap paramerters  overwrites the- Xmx Xms settings. It is possible that the max heap specified in the TRA file is quite less. Also, max heap has to be greater than min heap.

Check the TRA files  &ltTibcoHome>/tra/domain/&ltdomain>/\application/&ltapplicationName>. You could also start the cmd file from  that folder in a terminal session and verify the output.

Issue/Introduction

Deployment of BE engine fails on a Unix server for both inside and outside the administrator domain.