Event Type: Error Event Source: TIBCO iProcess Engine Event Category: None Event ID: 0 … Description: The description for Event ID ( 0 ) in Source ( TIBCO iProcess Engine ) cannot be found. The local computer may not have the necessary registry information or message DLL files to display messages from a remote computer. You may be able to use the /AUXSOURCE= flag to retrieve this description; see Help and Support for details. The following information is part of the event: TIBCO iProcess Engine error : 0x80040154
, CSWEventInstall(): CoCreateInstance() failed.
Event Type: Error Event Source: Staffware iProcess Engine Event Category: None Event ID: 0 … Description: The description for Event ID ( 0 ) in Source ( Staffware iProcess Engine ) cannot be found. The local computer may not have the necessary registry information or message DLL files to display messages from a remote computer. You may be able to use the /AUXSOURCE= flag to retrieve this description; see Help and Support for details. The following information is part of the event: Staffware iProcess Engine Assertion, Staffware Service: failed to start the Staffware COM+ Event component.
Environment: ========== TIBCO iProcess Engine 10.6.3.4 SQL 2005 Windows server 2003 (x64 architecture) with SP1
Symptoms: ========= Unable to start up iProcess Engine, the process sentinels start but no other processes are able to be started.
Cause: ===== The comadmin.dll was not registered.
Resolution: ========= The comadmin.dll needs to be re-registered if a CoCreate issue happens that occurred in the logs.
Process Monitor would show that the comadmin.dll was not registered.
Use process monitor to start a trace, restart the TIBCO service and then stop the trace. The trace will show that it failed to find the following clsid:
procmgr.exe 5268 RegOpenKey HKCR\Wow6432Node\CLSID\{F618C514-DFB8-11D1-A2CF-00805FC79235} NAME NOT FOUND
CLSID is from comadmin.dll. Code is accessing the COM Admin objects in order to run a query against the EventSystem service but failing to event create that COMAdmin component. Resolve by registering the .dll using c:\windows\syswow64\regsvr32.exe comadmin.dll.
Issue/Introduction
Issue starting up iProcess Engine, the process sentinels start but no other processes are able to be started.