Is there is a way to restrict network failure detection parameters of the TIBCO Enterprise Message Service (EMS) server (i.e. heartbeat and timeout) to be applicable only for specific client applications connecting to the EMS server?
book
Article ID: KB0088391
calendar_today
Updated On:
Products
Versions
TIBCO Enterprise Message Service
-
Not Applicable
-
Description
Resolution: Description: = = = = = =
There are six network failure detection parameters that can be configured in the EMS server. Depending on their values the server can detect a disconnection from a client or another server and vice-versa.
These parameters are specified in the main configuration file (tibemsd.conf) of the EMS server and are applicable for all client applications connecting to that EMS server. There is no way to chose different values for these parameters for different client connections.
Environment: = = = = = = = All
Keywords: = = = = = = Heartbeat connection
Issue/Introduction
Is there is a way to restrict network failure detection parameters of the TIBCO Enterprise Message Service (EMS) server (i.e. heartbeat and timeout) to be applicable only for specific client applications connecting to the EMS server?