Products | Versions |
---|---|
TIBCO Silver Center | - |
Not Applicable | - |
Description:
TIBCO Silver BPM 32-bit instances cannot be started in the eu-west-1 region due to a corrupted image.
Environment:
===========
- TIBCO Silver BPM 1.0.1
Symptoms:
========
Using TIBCO Silver Center to start a 32-bit instance running TIBCO Silver BPM will fail. There will initially be a notification of the instance starting but after a short time an error starting the instance will be reported.
Cause:
=====
The TIBCO Silver BPM 32-bit software image is corrupted.
Resolution:
==========
Run a 32-bit instance in other regions other than eu-west-1. If the requirement is to run anything in the eu-west-1 then run 64-bit instances.
Symptoms:
Cause: