TIBCO Adapter(TM) for Tuxedo supports specifying multi-WSNADDR for one instance to failover between Fault Tolerant Tuxedo servers.

TIBCO Adapter(TM) for Tuxedo supports specifying multi-WSNADDR for one instance to failover between Fault Tolerant Tuxedo servers.

book

Article ID: KB0088020

calendar_today

Updated On:

Products Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for Oracle Tuxedo -
Not Applicable -

Description

Resolution:
TIBCO Adapter(TM) for Tuxedo can support specifying multi-WSNADDR for one instance to failover between Fault Tolerant Tuxedo servers. This can be achieved by starting the adapter after modifying the adtuxedo_wrkstn.tra file’s WSNADDR entry in the following way:

------
tibco.env.WSNADDR //server_address_1:port_number_1,//server_address_2:port_number_2
------
Please note that the IP Addresses are separated by a comma (,)

Issue/Introduction

TIBCO Adapter(TM) for Tuxedo supports specifying multi-WSNADDR for one instance to failover between Fault Tolerant Tuxedo servers.