Products | Versions |
---|---|
TIBCO Object Service Broker for z/OS | - |
Not Applicable | - |
Resolution:
PROBLEM
=========
Installations that use TCP/IP Address Space name that is other than the default are required to specify this name in Relay XML file. However, this override is not honored causing OSB to attempt to use the default name (typically "TCPIP") and the attempt then fails with ERRNO=1011.
Messages which indicate a stack name error may include:
S6BRA005E Initialization of TCP/IP communications RELAY task failed
S6BRA012E Connection to node "nnnnnnnn" failed; CONNECT socket request failed with errno=1011
S6BRA040E Connection to TCP/IP interface failed with errno=1011
SOLUTION
=========
Please track JIRA issue OSBZ-1275 for the availability of a fix for this problem.
The fix for this problem is:
AP13521 Correct S6BRE012 relay number
to be delivered in a future hotfix for TIBCO Object Service Broker for z/OS 5.2.0.
REFERENCES
===========
General information about TCP/IP configuration is available in the following manuals:
IBM: IP and SNA Codes
IBM: IP Configuration Guide
IBM: IP Configuration Reference
TIBCO: TIBCO® Object Service Broker for z/OS Installing and Operating
TIBCO: TIBCO® Object Service Broker Messages With Identifiers
History
=======
March 24, 2011 - Issued.
June 22, 2011 - Added reference to fix identification AP13521.