When starting the TIBCO Adapter for Siebel 6.0 on TIBCO Runtime Agent 5.7, the adapter fails to start up.

When starting the TIBCO Adapter for Siebel 6.0 on TIBCO Runtime Agent 5.7, the adapter fails to start up.

book

Article ID: KB0089478

calendar_today

Updated On:

Products Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for Siebel -
Not Applicable -

Description

Resolution:
Description:
============
While trying to start the TIBCO Adapter for Siebel 6.0 on TIBCO Runtime Agent 5.7, the TIBCO Adapter for Siebel 6.0 throws the following error:

Exception in thread "main" java.lang.UnsatisfiedLinkError: net (A file or directory in the path name does not exist.)



Environment:
===========
   -- AIX 5.3
   -- TIBCO Adapter for Siebel 6.0
   -- TIBCO Runtime Agent 5.7
  
Resolution:
===========
  
In the adsbl.tra file, add the following to tibco.env.LIBPATH:
&ltTIBCO_HOME>/tibcojre/1.6.0/lib/ppc

Issue/Introduction

When starting the TIBCO Adapter for Siebel 6.0 on TIBCO Runtime Agent 5.7, the adapter fails to start up.