EMS 6.0 server crashed when it tried to destroy consumer on routed temp queues, the temp queues were routed between EMS 6.0 and EMS 4.2 or 4.3 servers.
book
Article ID: KB0090003
calendar_today
Updated On:
Products
Versions
TIBCO Enterprise Message Service
-
Not Applicable
-
Description
Resolution: Problem Description: ========================== EMS 6.0 server crashed when it tried to destroy consumers on routed temp queues. The temp queues were routed between EMS 6.0 and EMS 4.2 or 4.3 servers.
Cause: ======================= This problem was introduced in EMS 6.0 server because of the routing incompatibility between EMS 4.2 or 4.3 and 6.0 servers which causes repeated destruction of the same temporary queue.
The problem only occurs when configuring a route between EMS 6.0 and EMS 4.2 or 4.3 servers. It does not happen between EMS 6.0 and EMS 4.4.x servers.
The issue was resolved by the combination of fixes in 6.0.1. Customers should update their EMS 4.2 or 4.3 server to the latest EMS version. If they still have 4.2 or 4.3 servers within their routing infrastructure and can not upgrade, they can upgrade their EMS 6.0 server to EMS 6.0.1 to avoid EMS 6.0 server crash.
Issue/Introduction
EMS 6.0 server crashed when it tried to destroy consumer on routed temp queues, the temp queues were routed between EMS 6.0 and EMS 4.2 or 4.3 servers.