TIBCO(R) Adapter for SWIFT is not able to be startup with error “TIBSWF202501: Error: TRA 5.5.0 and above is a pre-requisite for installing” .
book
Article ID: KB0089413
calendar_today
Updated On:
Products
Versions
TIBCO Adapter for SWIFT
-
Not Applicable
-
Description
Resolution: Description: ============ When customer attempts to install the TIBCO(R) Adapter for SWIFT 5.7.0 on TRA 5.6.0, the installation fails starting with the error:
TIBSWF202501: Error: TRA 5.5.0 and above is a pre-requisite for installing. Please first install TRA 5.5.0 and proceed with this product installation.
Environment: =========== All 5.x versions
Cause ========== The installed TRA 5.6 could not be detected from the registry files by TIBCO(R) Adapter for the SWIFT installer program.
Resolution: ========== All TIBCO products including TRA should be registered in the registry files vpd.properties and vpd.properties.tibco.<systemName>, and the content of two registry files should be the same.
For this issue we suggest the following steps.
(1). Make sure there was no change in the <systemName> of the system after installation of TRA. If the hostname has cvhanged you need to update the file name of vpd.properties.tibco.<systemName>.
(2). If the content of the two registry files is not the same copy vpd.properties.tibco.<systemName> to vpd.properties to make the content identical.
(3). For Unix platforms, check the current user if vpd.properties.tibco.<systemName> has write/read permission.
(4). Do not have multiple users using the same user account installing TIBCO product at the same time.
(5). Stop all TIBCO processes before installing/uninstalling any TIBCO product.
(6). Make backups of the 'vpd.properties.tibco.< systemName >' file periodically after an installation so that the file can be restored if necessary.
Issue/Introduction
TIBCO(R) Adapter for SWIFT is not able to be startup with error “TIBSWF202501: Error: TRA 5.5.0 and above is a pre-requisite for installing” .