After changing the EXECSTACKSIZE parameter, does the Data Object Broker (DOB) or Service Gateway regions need to be re-cycled?
book
Article ID: KB0094267
calendar_today
Updated On:
Products
Versions
TIBCO Service Gateway for IMS/DB
-
Not Applicable
-
Description
Resolution: Description: ============ There are many parameters that can be modified to customize the behaviour of an Execution Environment (EE) region. Once such changes are made, is it necessary to recycle any associated DOB or Gateway regions?
Environment: ============ All environments supported by TIBCO Object Service Broker.
Resolution: =========== Most EE parameters, such as EXECSTACKSIZE, affect only the EE region itself so it is not necessary to recycle either the DOB or the DOB-connected Gateway regions.
References: =========== TIBCO® Object Service Broker for Open Systems Installing and Operating TIBCO® Object Service Broker for z/OS Installing and Operating TIBCO® Object Service Broker Parameters
Issue/Introduction
After changing the EXECSTACKSIZE parameter, does the Data Object Broker (DOB) or Service Gateway regions need to be re-cycled?