Routine "@MOMCALL" failed with Exception "MOM_NO_MQSSTUB" signaled

Routine "@MOMCALL" failed with Exception "MOM_NO_MQSSTUB" signaled

book

Article ID: KB0094140

calendar_today

Updated On:

Products Versions
TIBCO Service Gateway for WMQ (Open Systems) -
Not Applicable -

Description

Resolution:
Description:
============
MQSeries applications fail with the "MOM_NO_MQSSTUB" exception.

Environment:
============
o any z/OS version of OSB

Symptoms:
=========
MQSeries applications fail with the "MOM_NO_MQSSTUB" exception.

Cause:
======
This exception means that the Batch MQSeries stub is not linkedited into the S6BDRSES/HRNDRSES load module. This is normally for 1 of 2 reasons.

1) The MQSeries usermod has not been installed.

2) The MQSeries usermod has been regressed by application of SMP maintenance to S6BDRSES.


Resolution:
===========
Increase the REWORK() level of the usermod, if it has been previously installed, and RECEIVE and APPLY the usermod.

References:
===========
TIBCO® Object Service Broker for z/OS Installing and Operating - Installing the Service Gateway for WMQ

Issue/Introduction

Routine "@MOMCALL" failed with Exception "MOM_NO_MQSSTUB" signaled