EDIFACT validation issue "No such file or directory" when using BusinessConnect EDI Protocol 5.X.
book
Article ID: KB0087992
calendar_today
Updated On:
Products
Versions
TIBCO BusinessConnect EDI Protocol Powered by Instream
-
Not Applicable
-
Description
Resolution: Description: ============ When processing an inbound EDIFACT document, validation fails with the message, "Module could not be loaded: /opt/tibco/bc/5.2/protocols/edi/tpcl/lib/libSlnEDI.so. No such file or directory"
Environment: ========== BusinessConnect EDI Protocol 5.X. Solaris 10
Symptoms: ========= In the audit and BC interior logs, the message is shown as being rejected because of validation error but there is no description. Only when enabling the logging\store location under the trading partner settings, the " no such file or directory" description appears in the BusinessConnect*.log file. The following two lines are in the BC logs . There is no other description in the logs ******** 2012 Apr 18 16:57:33:876 GMT +1 BW.BusinessConnect-Single_Server Debug [bw.logger] BW-EXT-LOG-300002 No native data returned. There are errors encountered. 2012 Apr 18 16:57:34:078 GMT +1 BW.BusinessConnect-Single_Server Debug [bw.logger] BW-EXT-LOG-300002 +++ XML to EDI conversion error count = 1 ********
Cause: ===== EDI protocol files are not correctly installed.
Resolution: ========= Re-installing the EDI protocol will resolve the issue..
Issue/Introduction
EDIFACT validation issue "No such file or directory" when using BusinessConnect EDI Protocol 5.X.