Unable to start CIM server when no network is available.

Unable to start CIM server when no network is available.

book

Article ID: KB0091020

calendar_today

Updated On:

Products Versions
TIBCO Collaborative Information Manager -
Not Applicable -

Description

Resolution:
Description:
============
Error when trying to start the CIM server when the host machine is not connected to any network.

--
2012-08-21 11:23:54,536 [main] ERROR com.tibco.mdm.infrastructure.cache.MqCacheManagerActiveSpaces - Error connecting to metaspace com.tibco.as.space.ASException: TIBAS_SYS_ERROR (pgm initialize failure - Unknown parameter)
2012-08-21 11:23:54,674 [main] ERROR com.tibco.mdm.infrastructure.globalobj.MqStartupWrapper - Startup encountered MqException. Check the log files.
2012-08-21 11:30:12,356 [main] ERROR com.tibco.mdm.infrastructure.cache.MqCacheManagerActiveSpaces - Error connecting to metaspace com.tibco.as.space.ASException: TIBAS_SYS_ERROR (pgm initialize failure - Unknown parameter)
2012-08-21 11:30:12,504 [main] ERROR com.tibco.mdm.infrastructure.globalobj.MqStartupWrapper - Startup encountered MqException. Check the log files.
2012-08-21 11:33:00,605 [main] ERROR com.tibco.mdm.infrastructure.cache.MqCacheManagerActiveSpaces - Error connecting to metaspace com.tibco.as.space.ASException: TIBAS_SYS_ERROR (pgm initialize failure - Unknown parameter)
2012-08-21 11:33:00,730 [main] ERROR com.tibco.mdm.infrastructure.globalobj.MqStartupWrapper - Startup encountered MqException. Check the log files.
--

References:
===========
http://www.windowsreference.com/windows-7/how-to-install-a-loopback-adapter-in-windows-7/

Environment:
===========
TIBCO Collaborative Information Manager(CIM) 8.2.1.

Cause:
=====
Loop Back adapter not configured.

Resolution:
==========
Configure the loop back adapter on the system by using the recommendation at   http://www.windowsreference.com/windows-7/how-to-install-a-loopback-adapter-in-windows-7/

Issue/Introduction

Unable to start CIM server when no network is available.