Data starting at position 0 is not recognized as a valid data transmission.
book
Article ID: KB0090510
calendar_today
Updated On:
Products
Versions
TIBCO BusinessConnect EDI Protocol Powered by Instream
-
Not Applicable
-
Description
Resolution: Description: ========== Customer is trying to create an X12 interface as follows: Under EDI-X12 they created 00401 as interchange version then 004010 as group version and 204 as the operation. A validation error occurs when a transaction is processed. .
Symptoms: ========= The validation error is:
Category: Rejecting Severity: Normal Brief: : Parser error - No matching parser schema was found. [ID=0x2010003] Details: The data starting at position 0 is not recognized as a valid data transmission. ID: 0x2010003
Environment: ========== BusinessConnect EDI 6.x versions
Resolution: =========== This issue occurs because BC is trying to generate the TA1 acknowledgement to send back to your trading partner, but it can not find the TA1 definition needed.
To resolve this issue try following:
1). Create a group called "EmptyGroup" under the 00401 interchange (you do not need to define any group properties).
2). Create a transaction called "TA1" under this group.
You do not need to assign an .sef file or mapping files to the TA1 transaction. BC will find the correct files automatically.
Issue/Introduction
Data starting at position 0 is not recognized as a valid data transmission.