List of variables/elements that are supported macros (-999) in private process EDI outbound payload (XML).
book
Article ID: KB0087729
calendar_today
Updated On:
Products
Versions
TIBCO BusinessConnect EDI Protocol Powered by Instream
-
Not Applicable
-
Description
Resolution: Description: ============ When you specify -999 in the private process EDI payload (xml), BC engine recognizes this value and replaces it with the actual value at runtime. What are all the variables/elements that are supported macros (-999) in private process outbound payload (XML)?
Environment: ============ TIBCO BusinessConnect EDI Protocol 6.x.x version
Symptoms: ========= The private process can send -999 as a macro for few variables/elements in outbound EDI payload (XML) and I can see the same -999 value is going out in outbound EDI document.
Cause: ====== The macros i.e. -999 value is supported by few variables/elements only.
Resolution: =========== The elements ST_02 and SE_02 in X12, UNH_01 and UNT_02 in Edifact elements will only be replaced by BCEDI at runtime.
Issue/Introduction
List of variables/elements that are supported macros (-999) in private process EDI outbound payload (XML).