TIBCO BusinessWorks Collaborator (BWC) Repository Server Fails to start after a change in RV parameters.

TIBCO BusinessWorks Collaborator (BWC) Repository Server Fails to start after a change in RV parameters.

book

Article ID: KB0089188

calendar_today

Updated On:

Products Versions
TIBCO BusinessWorks Collaborator -
Not Applicable -

Description

Description:
TIBCO BusinessWorks Collaborator(BWC) Server and Repository Server stores the configuration into icconfig.xml and icrepconfig.xml files respectively. After any changes in the mentioned config files, BWC Server or Repository Server fails to start.

Symptoms:
  • BWC Server or Repository Server fails to start.
  • Export to BWC Server or Repository server indicates that the server is not available.

Cause:
  • Non formed/invalid XML Tags makes BWC server and Repo Server fails to read the correct configuration.

Issue/Introduction

TIBCO BusinessWorks Collaborator (BWC) Repository Server Fails to start after a change in RV parameters.

Resolution


To identify specific XML tag issues in the config files, the following can done.

  1.  Launch command prompt (console) and go to the /domain// and launch the start-up cmd file created for the repo server. The console will display the SAX parser exception and indicate which XML tag (for example, Rvservice parameter defined in the icrepconfig.xml) failed to parse.
  2. You can try to open config files using a browser such as Internet Explorer (IE) to display the parsing error. This can help identify the issue that was caused by the bad XML tag or any typos.
After correcting the tags, the BWC Server or Repo Server should start.