EDI schemas do not get loaded into Designer when importing from BusinessConnect.
book
Article ID: KB0085472
calendar_today
Updated On:
Products
Versions
TIBCO BusinessConnect EDI Protocol Powered by Instream
-
Not Applicable
-
Description
Description: When doing an import of an X12, EDIFACT, or TEXT schema into TIBCO Designer, the import operation succeeds but the schema does not appear in Designer. Symptoms: As described above. Cause: In the TIBCO BusinessConnect operations editor for the transaction in question, the root element is not specified or is incorrectly set.
Issue/Introduction
EDI schemas do not get loaded into Designer when importing from BusinessConnect.
Resolution
Under the Schema tab of the Transaction specification under Administrator>BusinessConnect>Operation Editor, make sure that the "Request Root Element Name" is set to the correct value. This value is a string that usually starts with "T-" as exported from EDISIM.
Additional Information
TIBCO BusinessConnect EDI Protocol User's Guide, EDISIM.