BusinessConnect EDI Protocol powered by Instream 6.5.0 install fails when used with BusinessConnect 6.2.0.

BusinessConnect EDI Protocol powered by Instream 6.5.0 install fails when used with BusinessConnect 6.2.0.

book

Article ID: KB0093335

calendar_today

Updated On:

Products Versions
TIBCO BusinessConnect EDI Protocol Powered by Instream -
Not Applicable -

Description

Description:
When installing the BC EDI 6.5.0 protocol on BC 6.2.0, the following error is seen:

/opt/mis/apps/tibco/bc/6.2/protocols/tibedi/setup/post-install.xml:156: The following error occurred while executing this line:
/opt/mis/apps/tibco/bc/6.2/protocols/tibedi/setup/post-install.xml:36: Warning: Could not find file /opt/mis/apps/tibco/bc/6.1/protocols/tibedi/tools/updateWinRegistry/UpdateRegistry.tra_template to copy.

Symptoms:
See description.
Cause:
The EDI 6.5 installer is not updated to support BusinessConnect 6.2.0 .

Issue/Introduction

BusinessConnect EDI Protocol powered by Instream 6.5.0 install fails when used with BusinessConnect 6.2.0.

Resolution

BC EDI 6.6.0 is recommended rather than EDI 6.5.0 with BC 6.2.0. EDI 6.6 is available on the TIBCO eDelivery download site:  eDelivery.tibco.com.


Additional Information

None