"Error connecting to server, Check if TIBCO Business Events Web Studio server is running" error when trying to "Generate Deployable" from WebStudio.
book
Article ID: KB0093482
calendar_today
Updated On:
Products
Versions
TIBCO BusinessEvents Enterprise Edition
-
Not Applicable
-
Description
Description: While doing "Generate Deployable" option in WebStudio, error pop-up "Error connecting to server, Check if TIBCO Business Events Web Studio server is running" This error was seen even when the Rules Management Server was running and the "Generate Deployable" was successful after sometime.
Issue/Introduction
"Error connecting to server, Check if TIBCO Business Events Web Studio server is running" error when trying to "Generate Deployable" from WebStudio.
Resolution
The error is seen when the "Generate Deployable" operation is taking more time than the specified timeout ("tibco.clientVar.Webstudio/Connection/timeout") in the RMS.cdd file. The default value of tibco.clientVar.Webstudio/Connection/timeout is 60000. Set the timeout to an appropriate value for your specific environment or set it to -1 (unlimited) to fix the issue.