Messages published by the publication service of TIBCO ActiveMatrix Adapter for SAP are expired by EMS even if the expiration property of the EMS destination is not set.
book
Article ID: KB0093008
calendar_today
Updated On:
Products
Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for SAP Solutions
-
Not Applicable
-
Description
Description: The activity of expiring messages on an EMS destination is not only related to the "expiration" property of the EMS destination but also depends on the setting of "Message Timeout" on the Publisher endpoint which is used for publishing messages from adapter publication service to EMS.
Issue/Introduction
Messages published by the publication service of TIBCO ActiveMatrix Adapter for SAP are expired by EMS even if the expiration property of the EMS destination is not set.
Resolution
Set the value of "Message Timeout(ms)" on the Publisher endpoint in Design time project to 0. Rebuilding a new project EAR is required so that the change regarding the Design time project can take effect on the Run time adapter instance by redeploying the newly created project EAR.