Substation ES CICS transactions will abend when used with CICS TS 5.1
book
Article ID: KB0093600
calendar_today
Updated On:
Products
Versions
TIBCO Substation ES
-
Not Applicable
-
Description
Description: When multiple CICS interfaces are connected to one CICS region, transactions may abend. Abend codes AAL8 and ATDC have been observed for these transactions. The cause of the problem is a deadlock in CICS 5.1, for which IBM has provided an APAR to rectify the situation. When using CICS TS 5.1, IBM APAR PM98235 should be applied to CICS.
Symptoms: Transactions abend with codes such as AAL8, ATDC have been observed.
Cause: This is a CICS deadlock issue identified by IBM.
Issue/Introduction
Substation ES CICS transactions will abend when used with CICS TS 5.1
Resolution
To fix this issue apply IBM APAR: PM98235 PTF: UI12853.