Description
Publication service unable to parse the input records 2015 Aug 25 18:15:28:262 GMT -0300 Trying to match with /tibco/public/class/ae/FileAdapter/native/FileAdapterConfiguration/SubCod99 2015 Aug 25 18:15:28:262 GMT -0300 This is a delimited class 2015 Aug 25 18:15:28:262 GMT -0300 Line matching class /tibco/public/class/ae/FileAdapter/native/FileAdapterConfiguration/SubCod99 2015 Aug 25 18:15:28:262 GMT -0300 New child found 2015 Aug 25 18:15:28:265 GMT -0300 FileAdapter.FileAdapterConfiguration Info [Adapter] AEFA-000065 Message containing class /tibco/public/class/ae/FileAdapter/wire/FileAdapterConfiguration/SubCod00 published on subject teste.queue (message is from file C:\temp\trash\working\ap15232143914.txt) tracking=#Jk2--2--JRnOw-EU--Sqk8U0I--KE#tracking#Jk2--2--JRnOw-EU--Sqk8U0I--KE#FileAdapter#FileAdapterConfiguration#C:\temp\trash\working\ap15232143914.txt#
Symptoms: The TIBCO ActiveMatrix® Adapter for Files for Unix/Win(FA) 6.2 discards and not sending the row like expected. When FA is used in the Display Wizard and pressed the button to create the Attributes, based on file it returns some missing rows/data while using a Publication Service.
Cause: TIBCO ActiveMatrix® Adapter for Files for Unix/Win(FA) Publisher fails to parse record having no value between two delimiters with schemas Identifier Type "Number of Fields". The problem is coming because of "Repeating" checkbox in File Schema is checked.
Issue/Introduction
TIBCO ActiveMatrix® Adapter for Files 6.2(Unix/Win)FA missing some rows/data while using a PublicationService.
Environment
All Supported Operating Systems
Resolution
TIBCO ActiveMatrix® Adapter for Files for Unix/Win(FA) Publisher fails to parse record having no value between two delimiters with schemas Identifier Type "Number of Fields" due to the checked "Repeating" checkbox in File Schema.
Repeating Delimiter check box option specifies whether to ignore repeated delimiters in the input file. Selecting this check box translates any repeated delimiters between fields as only one field separator. Clearing the check box translates the repeated delimiters as empty fields.
Go to File Schemas in the publication Service >> Delimited File Record >> Configuration and un-check the 'Repeating' checkbox. --------------------------------------------------------------------