Description: EMS installation stops at the step "Checking /Updating machine model".
Symptoms: When
running Installer in GUI install mode, the Installer stops at the step "Checking /Updating machine model". The following information is also shown.
-set-install-support-properties:
-define-antcontrib-tasks:
-define-install-support-tasks:
-check-properties:
-legacy-sync-machine-model:
-named-sync-machine-model:
[install.support.create.machine.model]
Machine model at
/home/adfile/tibco/tools/machinemodel/shared/1.0.0/machine.xmi already
exists, nothing done
[install.support.sync.machine.add]
Synchronizing machine model to add release units in installation file
state at
file:/home/adfile/tibco/tools/machinemodel/shared/1.0.0/machine.xmi
BUILD FAILED
/home/adfile/tibco/tools/scripts/sync-machine-model.xml:42:
Error synchronizing machine model to add release units in installation
file state: Could not install components: TIBCO-AMX-INFRA-000193:
Machine file at
"file:/home/adfile/tibco/tools/machinemodel/shared/1.0.0/machine.xmi"
could not acquire the lock; it is locked by
"bbdc6c69-e106-4435-97a4-373091ef316d"
Total time: 1 minute 0 seconds
WARNING: Sync Machie Model Failed.
Cause: The machine.xmi and machine.xmi.lck under
tools\machinemodel\shared\<version> were created by other user
and other user group