Error during TIBCO Spotfire Web Player installation: "Error 1722.There is a problem with this Windows Installer package. A program run as part of the setup did not finish as expected. "

Error during TIBCO Spotfire Web Player installation: "Error 1722.There is a problem with this Windows Installer package. A program run as part of the setup did not finish as expected. "

book

Article ID: KB0082242

calendar_today

Updated On:

Products Versions
Spotfire Web Player 7.0 and lower

Description

This issue may be seen during the TIBCO Spotfire Web Player installation, when the installer tries to install the Performance Counters:
"Error 1722.There is a problem with this Windows Installer package. A program run as part of the setup did not finish as expected. "
  • When the Web Player installer is run, the registry settings related to the installation for Performance Counters are not properly set if the performance counters are corrupted on the Windows Operating System level.

Issue/Introduction

This article lists the resolution of how to handle errors that occur when Performance Counters are set up during the installation of TIBCO Spotfire Web Player, and the following error is seen: "Error 1722.There is a problem with this Windows Installer package. A program run as part of the setup did not finish as expected. "

Resolution

To resolve, fix the corrupted performance counters. Please use following references on how to rebuild performance counters on your server: After fixing the performance counters, perform the TIBCO Spotfire Web Player installation again.

Additional Information

External: How to rebuild performance counters on Windows Vista/Server2008/7/Server2008R2 External: Lodctr