studio-tools do not run correctly after renaming the executable.

studio-tools do not run correctly after renaming the executable.

book

Article ID: KB0092812

calendar_today

Updated On:

Products Versions
TIBCO BusinessEvents Enterprise Edition -
Not Applicable -

Description

Description:
When studio-tools is renamed, for example when you want a script to actually call the studio-tools executable, it fails because it can not find the studio-tools.tra file.

Symptoms:
See description.

Cause:
The executable looks for a TRA file which has the same name as the executable file without the extension, if any.

Issue/Introduction

studio-tools do not run correctly after renaming the executable.

Environment

Product: TIBCO BusinessEvents Version: 5.x OS: All Supported Operating Systems --------------------

Resolution

Either rename the studio-tools.tra to the new name of the binary or pass in the name of the TRA file. If stdio-tools was renamed to studio-tools-binary, then the command line becomes "studio-tools-binary —propFile studio-tools.tra".  Note the double hyphen.