Error while upgrading TIBCO iProcess Engine 11.3.0.

Error while upgrading TIBCO iProcess Engine 11.3.0.

book

Article ID: KB0093029

calendar_today

Updated On:

Products Versions
TIBCO iProcess Engine (Oracle) -
Not Applicable -

Description

Description:
Upgrade fails because uorai<ver>.sql scripts are run for versions earlier than the current TIBCO iProcess Engine (iPE) version.

Symptoms:
When the option to upgrade files and database is chosen, during the Oracle upgrade section, uora<ver>.sql scripts are run for earlier versions of iPE resulting in errors being written to the tablelog. The errors relate to tables already existing, for example:

About to configure Oracle database to run TIBCO iProcess Engine
Configuring DB Users ...
Upgrading Oracle Tables (This may take some time) ...
Running upgrade script uorai111_00.sql


**********************************************
**********************************************
Possible errors located in logfile /TIBCO/iPE/swnod1/logs/uorai111_00-7051.tablelog
**********************************************
**********************************************
Cause:
The user running the installation does not have write permission to the temporary directory used for the iPE installation set.

Issue/Introduction

Error while upgrading TIBCO iProcess Engine 11.3.0.

Resolution

Ensure the user performing the upgrade has write permissions on the iPE installation set temporary directory.