TIBCO Administrator 5.4.0 Hotfix 1 has been released
book
Article ID: KB0106171
calendar_today
Updated On:
Products
Versions
TIBCO Administrator
-
Not Applicable
-
Description
Description: You can download this HotFix from the TIBCO Product Support FTP server using your eSupport username and password, at ftp://support-ftp.tibco.com
Once you have successfully logged into the server, you will find the hotfix packages under ActiveEnterprise/TIBCOAdministrator/5.4.0/hotfix-1
Listed below is a summary of updates included. Please refer to the associated readme document for any additional information.
1-7YACCN Global variable values were jumbled after modifying the value and clicking the Save button in the configuration panel. This happens in projects where there are many global variables (200+). The issue occurs on AIX platforms, but could happen on all platforms.
To work around this issue, add the following line in the tibcoadmin_<domain>.tra file. This property exists in 5.4.0, but is not exposed in the tibcoadmin_<domain>.tra file.
java.property.WFC.SILK_SUPPORT_ENABLED=true
1-8BILHL Fixed the handling of commit notifications. Applications would unnecessarily load entire configurations and consume a lot of memory even when deployment was done using AppManage.
1-8C0780 When catching EntityRuntimeException, the logic in getting the exception could result in an infinite loop. This has been fixed.
1-81B08C Exception when clicking on properties in deployed configuration screen. This has been fixed.
Issue/Introduction
TIBCO Administrator 5.4.0 Hotfix 1 has been released